xpower duct talent
xpower duct mobile
inverter

INVERTER

POWER SAVING TECHNOLOGY, HIGH COOLING BUT LOW POWER

quietly-astonishing

QUIET

SOUND LEVEL IS QUIETER

health-protection

INNOVATIVE HEALTH PROTECTION

COATING WITH AQUA RESIN, DUST PROTECTING AND HELP RESTRICTING BACTERIA INFECTIOUS

energy-efficient

ENERGY EFFICIENT

POWER SAVING WITH SEER UP TO 21.15 (SAVE MORE THAN NORMAL POWER 30%)

waranty_2_7

WARRANTY

COMPRESSOR WARRANTY 7 YEARS AND WARRANTY OF PARTS 2 YEARS

xpower duct 1

Aesthetics of living

Space of creativity

Ducted type air-conditioner is one of the inspirations from ‘Carrier’ for increasing the delighting space. Making your residence be more creative workspace by the inexhaustible cooling power for the boundless happiness, fantasize and let you be yourself extremely.

Happiness surround

The environment you desire

Carrier not offered you only the cool, we are behind all the happiness of you and your beloved. The Coolness, Clean and fresh air we offer to you are relating inspiration to refresh the power all around you by the smile and special feeling for the special moments of you and your family.

xpower duct 2
xpower_cassette_5

Intelligent working

Twin-Rotary Compressor

Carrier inverter with Twin-rotary system offered you more than cooling by the meticulous in production, product development for the maximum power saving you can choose because your happiness and comfortable are the important thing we never overlooked and bothered over 117 years.

Aesthetics of living

Space of creativity

Ducted type air-conditioner is one of the inspirations from ‘Carrier’ for increasing the delighting space. Making your residence be more creative workspace by the inexhaustible cooling power for the boundless happiness, fantasize and let you be yourself extremely.

Happiness surround

The environment you desire

Carrier not offered you only the cool, we are behind all the happiness of you and your beloved. The Coolness, Clean and fresh air we offer to you are relating inspiration to refresh the power all around you by the smile and special feeling for the special moments of you and your family.

Intelligent working

Twin-Rotary Compressor

Carrier inverter with Twin-rotary system offered you more than cooling by the meticulous in production, product development for the maximum power saving you can choose because your happiness and comfortable are the important thing we never overlooked and bothered over 117 years.

carrier_button

The size of this BTU model. 

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
13,500

SEER
17.09 Btu/Hr./Watt

Power Consumption
1.12 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
9,134.18 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0131BP

Noise level (H/M/L)
33 / 29 / 25 dB (A)

Dimension (HxWxD)
Housing – 275 x 700 x 750 mm.

Net Weight
Housing – 23 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0131A1

Noise Level
47 dB(A)

Dimension (HxWxD)
550 x 780 x 290 mm.

Weight
33 kg.

Refrigerant
R410a

Compressor Type 
Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
10 m.

Maximum Pipe Length
20 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
16,518

SEER
17.13 Btu/Hr./Watt

Power Consumption
1.44 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
9,112.85 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0181BP

Noise level (H/M/L)
33 / 29 / 25 dB (A)

Dimension (HxWxD)
Housing – 275 x 700 x 750 mm.

Net Weight
Housing – 23 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0181A1

Noise Level
52 dB(A)

Dimension (HxWxD)
550 x 780 x 290 mm.

Weight
32 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
10 m.

Maximum Pipe Length
25 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
21,380

SEER
18.36 Btu/Hr./Watt

Power Consumption
1.78 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
13,465.20 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0241BP

Noise level (H/M/L)
41 / 37 / 34 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,000 x 750 mm.

Net Weight
Housing – 30 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0241A1

Noise Level
52 dB(A)

Dimension (HxWxD)
550 x 780 x 290 mm.

Weight
32 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
10 m.

Maximum Pipe Length
25 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
35,500

SEER
15.32 Btu/Hr./Watt

Power Consumption
3.47 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
26,794.62 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0361BP

Noise level (H/M/L)
44 / 42 / 39 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,000 x 750 mm.

Net Weight
Housing – 30 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0361A1

Noise Level
59 dB(A)

Dimension (HxWxD)
890 x 900 x 320 mm.

Weight
57 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
20 m.

Maximum Pipe Length
30 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
35,500

SEER
15.32 Btu/Hr./Watt

Power Consumption
3.47 Kw

Power Supply
380 V / 3 Phase / 50 Hz

Estimated Electricity Charge*
26,794.62 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0361BP

Noise level (H/M/L)
44 / 42 / 39 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,000 x 750 mm.

Net Weight
Housing – 30 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0361A3

Noise Level
59 dB(A)

Dimension (HxWxD)
890 x 900 x 320 mm.

Weight
48 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
20 m.

Maximum Pipe Length
30 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
42,600

SEER
14.66 Btu/Hr./Watt

Power Consumption
4.30 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
33,601.11 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0401BP

Noise level (H/M/L)
44 / 42 / 39 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,400 x 750 mm.

Net Weight
Housing – 40 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0401A1

Noise Level
60 dB(A)

Dimension (HxWxD)
890 x 900 x 320 mm.

Weight
57 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
20 m.

Maximum Pipe Length
30 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
42,600

SEER
15.04 Btu/Hr./Watt

Power Consumption
4.16 Kw

Power Supply
380 V / 3 Phase / 50 Hz

Estimated Electricity Charge*
32,752.14 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0401BP

Noise level (H/M/L)
44 / 42 / 39 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,400 x 750 mm.

Net Weight
Housing – 40 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0401A3

Noise Level
60 dB(A)

Dimension (HxWxD)
890 x 900 x 320 mm.

Weight
48 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
20 m.

Maximum Pipe Length
30 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

13,500 BTU

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
13,500

SEER
17.09 Btu/Hr./Watt

Power Consumption
1.12 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
9,134.18 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0131BP

Noise level (H/M/L)
33 / 29 / 25 dB (A)

Dimension (HxWxD)
Housing – 275 x 700 x 750 mm.

Net Weight
Housing – 23 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0131A1

Noise Level
47 dB(A)

Dimension (HxWxD)
550 x 780 x 290 mm.

Weight
33 kg.

Refrigerant
R410a

Compressor Type 
Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
10 m.

Maximum Pipe Length
20 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

16,518 BTU

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
16,518

SEER
17.13 Btu/Hr./Watt

Power Consumption
1.44 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
9,112.85 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0181BP

Noise level (H/M/L)
33 / 29 / 25 dB (A)

Dimension (HxWxD)
Housing – 275 x 700 x 750 mm.

Net Weight
Housing – 23 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0181A1

Noise Level
52 dB(A)

Dimension (HxWxD)
550 x 780 x 290 mm.

Weight
32 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
10 m.

Maximum Pipe Length
25 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

21,380 BTU

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
21,380

SEER
18.36 Btu/Hr./Watt

Power Consumption
1.78 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
13,465.20 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0241BP

Noise level (H/M/L)
41 / 37 / 34 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,000 x 750 mm.

Net Weight
Housing – 30 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0241A1

Noise Level
52 dB(A)

Dimension (HxWxD)
550 x 780 x 290 mm.

Weight
32 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
10 m.

Maximum Pipe Length
25 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

35,500 BTU

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
35,500

SEER
15.32 Btu/Hr./Watt

Power Consumption
3.47 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
26,794.62 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0361BP

Noise level (H/M/L)
44 / 42 / 39 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,000 x 750 mm.

Net Weight
Housing – 30 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0361A1

Noise Level
59 dB(A)

Dimension (HxWxD)
890 x 900 x 320 mm.

Weight
57 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
20 m.

Maximum Pipe Length
30 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

35,500 BTU

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
35,500

SEER
15.32 Btu/Hr./Watt

Power Consumption
3.47 Kw

Power Supply
380 V / 3 Phase / 50 Hz

Estimated Electricity Charge*
26,794.62 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0361BP

Noise level (H/M/L)
44 / 42 / 39 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,000 x 750 mm.

Net Weight
Housing – 30 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0361A3

Noise Level
59 dB(A)

Dimension (HxWxD)
890 x 900 x 320 mm.

Weight
48 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
20 m.

Maximum Pipe Length
30 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

42,600 BTU

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
42,600

SEER
14.66 Btu/Hr./Watt

Power Consumption
4.30 Kw

Power Supply
220 V / 1 Phase / 50 Hz

Estimated Electricity Charge*
33,601.11 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0401BP

Noise level (H/M/L)
44 / 42 / 39 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,400 x 750 mm.

Net Weight
Housing – 40 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0401A1

Noise Level
60 dB(A)

Dimension (HxWxD)
890 x 900 x 320 mm.

Weight
57 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
20 m.

Maximum Pipe Length
30 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

42,600 BTU

XPOWER

Duct INVERTER

SPECIFICATION

Cooling Capacity (BTU/hr)
42,600

SEER
15.04 Btu/Hr./Watt

Power Consumption
4.16 Kw

Power Supply
380 V / 3 Phase / 50 Hz

Estimated Electricity Charge*
32,752.14 Baht/yr

Compare Products

INDOOR UNIT MODEL

Model Name
42TSV0401BP

Noise level (H/M/L)
44 / 42 / 39 dB (A)

Dimension (HxWxD)
Housing – 275 x 1,400 x 750 mm.

Net Weight
Housing – 40 kg.

OUTDOOR UNIT MODEL

Model Name
38TSV0401A3

Noise Level
60 dB(A)

Dimension (HxWxD)
890 x 900 x 320 mm.

Weight
48 kg.

Refrigerant
R410a

Compressor Type 
Twin Rotary DC-Inverter

Expansion Device Valve

Minimum Pipe Length
20 m.

Maximum Pipe Length
30 m.

Capacity Test Condition

  *Refer to energy label No.5 by Electricity Generating Authority of Thailand (EGAT)

Consult detailed product information about this model anytime, anywhere on your personal computer or tablet device.

xpower duct ac

Consult detailed product information about this model anytime, anywhere on your personal computer or tablet device.

xpower duct ac

Consult detailed product information about this model anytime, anywhere on your personal computer or tablet device.

0